Research Article

Sensitivity Evaluation of AP1000 Nuclear Power Plant Best Estimation Model

Table 2

The influence of core channel node number on the reactor pressure drop.

Node numberReactor inlet pressure (MPa)Reactor outlet pressure (MPa)Calculated reactor pressure drop (MPa)Designed reactor pressure drop (MPa)Fractional error

515.754515.39440.36010.4316.26%
1015.834215.42130.41290.433.98%
1515.894715.39970.4950.4315.12%
2015.951615.40060.5510.4328.14%
3016.073915.60970.46420.437.95%
4016.132815.63150.50130.4316.58%
5016.167515.65890.50860.4318.28%