MCST, MFCLT, and maximum relative power during the CRDA with reactor SCRAM.
(a)

BOCInitialCR1CR2CR4CR6CR8CR10CR12CR15CR16

MCST (K)1119.71129.01133.71129.81334.01136.61141.61137.11149.31142.5
MFCLT (K)2436.92516.52549.22530.03307.92570.52578.92533.52536.22512.5
Max relative power1.01.2081.1941.2021.1211.2611.3211.2611.3441.191

(b)

EOCInitialCR4CR5CR7CR12CR15

MCST (K)1168.91187.01186.41190.81187.91185.8
MFCLT (K)2447.825362534255225352528