Results for CRDAs without SCRAM.
(a)

BOCInitialCR1CR2CR4CR6CR8CR10CR12CR15CR16

MCST (K)1119.7136313581369133313971450141114931431
MFCLT (K)2436.9285531393097330734783787337937353577
Max relative power1.01.2031.1891.1981.1191.2551.3121.2561.3331.189
New relative steady-state power-1.0311.0301.0291.0181.0351.0341.0341.0331.024

(b)

EOCInitialCR4CR5CR7CR12CR15

MCST (K)1168.914291450136414001458
MFCLT (K)2447.832333400312231003350
Max relative power1.01.2231.2851.2091.2431.295