Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM

Table 3

Monte Carlo simulation results of selected nuclides.

NuclidesAverage pulses emitted by the detector over the entire spectrum (100–3000 keV)
(count/particle)
Average pulses emitted by the detector in the characteristic spectrum interval of Kr-88 (785–885 keV)
(count/particle)
Estimated relative errorEstimated variance of the variance

Kr-85m2.674E – 040.00E + 000.02730.0007
Kr-874.102E – 047.00E – 060.02210.0005
Kr-884.302E – 041.28E – 050.02160.0005
Kr-894.050E – 047.20E – 060.02220.0005
Xe-1332.738E – 040.00E + 000.02700.0007
Xe-133m3.194E – 040.00E + 000.02500.0006
Xe-1353.312E – 040.00E + 000.02460.0006
Xe-135m3.760E – 040.00E + 000.02310.0005
Xe-1373.700E – 042.00E – 070.02320.0005
Xe-1383.948E – 042.60E – 060.02250.0005
I-1313.536E – 040.00E + 000.02380.0006
I-1324.040E – 043.00E – 060.02220.0005
I-1333.804E – 045.80E – 060.02290.0005
I-1344.084E – 043.16E – 050.02210.0005
I-1354.344E – 041.52E – 050.02150.0005
Rb-884.488E – 047.00E – 060.02110.0004
Cs-1383.616E – 040.00E + 000.02350.0006