Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM
Table 3
Monte Carlo simulation results of selected nuclides.
| Nuclides | Average pulses emitted by the detector over the entire spectrum (100–3000 keV) (count/particle) | Average pulses emitted by the detector in the characteristic spectrum interval of Kr-88 (785–885 keV) (count/particle) | Estimated relative error | Estimated variance of the variance |
| Kr-85m | 2.674E – 04 | 0.00E + 00 | 0.0273 | 0.0007 | Kr-87 | 4.102E – 04 | 7.00E – 06 | 0.0221 | 0.0005 | Kr-88 | 4.302E – 04 | 1.28E – 05 | 0.0216 | 0.0005 | Kr-89 | 4.050E – 04 | 7.20E – 06 | 0.0222 | 0.0005 | Xe-133 | 2.738E – 04 | 0.00E + 00 | 0.0270 | 0.0007 | Xe-133m | 3.194E – 04 | 0.00E + 00 | 0.0250 | 0.0006 | Xe-135 | 3.312E – 04 | 0.00E + 00 | 0.0246 | 0.0006 | Xe-135m | 3.760E – 04 | 0.00E + 00 | 0.0231 | 0.0005 | Xe-137 | 3.700E – 04 | 2.00E – 07 | 0.0232 | 0.0005 | Xe-138 | 3.948E – 04 | 2.60E – 06 | 0.0225 | 0.0005 | I-131 | 3.536E – 04 | 0.00E + 00 | 0.0238 | 0.0006 | I-132 | 4.040E – 04 | 3.00E – 06 | 0.0222 | 0.0005 | I-133 | 3.804E – 04 | 5.80E – 06 | 0.0229 | 0.0005 | I-134 | 4.084E – 04 | 3.16E – 05 | 0.0221 | 0.0005 | I-135 | 4.344E – 04 | 1.52E – 05 | 0.0215 | 0.0005 | Rb-88 | 4.488E – 04 | 7.00E – 06 | 0.0211 | 0.0004 | Cs-138 | 3.616E – 04 | 0.00E + 00 | 0.0235 | 0.0006 |
|
|