Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM
Table 4
Calculation of the detection efficiency of the online monitoring system over the entire spectrum (100–3000 keV).
| Nuclides | Average pulses emitted by the detector (count/particle ) | Total γ branch ratio (number of emitted photons per decay) | Detection efficiency [] | Activity concentration in the coolant in the exit of helium purification system (99.9% purification efficiency) (Bq·L–1) | |
| Kr-85m | 2.674E – 04 | 0.892670 | 1.848E – 04 | 60.00 | 1.11E – 02 | Kr-87 | 4.102E – 04 | 0.779675 | 2.476E – 04 | 67.00 | 1.66E – 02 | Kr-88 | 4.302E – 04 | 1.239245 | 4.127E – 04 | 140.00 | 5.78E – 02 | Kr-89 | 4.050E – 04 | 1.272980 | 3.991E – 04 | 20.00 | 7.98E – 03 | Xe-133 | 2.738E – 04 | 0.000712 | 1.509E – 07 | 850.00 | 1.28E – 04 | Xe-133m | 3.194E – 04 | 0.103000 | 2.547E – 05 | 28.00 | 7.13E – 04 | Xe-135 | 3.312E – 04 | 0.927948 | 2.379E – 04 | 130.00 | 3.09E – 02 | Xe-135m | 3.760E – 04 | 0.809970 | 2.358E – 04 | 14.00 | 3.30E – 03 | Xe-137 | 3.700E – 04 | 0.320150 | 9.170E – 05 | 42.00 | 3.85E – 03 | Xe-138 | 3.948E – 04 | 1.133639 | 3.465E – 04 | 93.00 | 3.22E – 02 | I-131 | 3.536E – 04 | 0.962891 | 2.636E – 04 | 0.18 | 4.74E – 05 | I-132 | 4.040E – 04 | 2.870846 | 8.978E – 04 | 2.30 | 2.06E – 03 | I-133 | 3.804E – 04 | 0.991557 | 2.920E – 04 | 0.92 | 2.69E – 04 | I-134 | 4.084E – 04 | 2.885958 | 9.124E – 04 | 4.70 | 4.29E – 03 | I-135 | 4.344E – 04 | 1.214136 | 4.083E – 04 | 1.40 | 5.72E – 04 | Rb-88 | 4.488E – 04 | 0.373961 | 1.299E – 04 | 7.70 | 1.00E – 03 | Cs-138 | 3.616E – 04 | 1.872362 | 5.241E – 04 | 1.60 | 8.39E – 04 |
| | 1.19E – 04 |
|
|