Research Article

Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM

Table 4

Calculation of the detection efficiency of the online monitoring system over the entire spectrum (100–3000 keV).

NuclidesAverage pulses emitted by the detector (count/particle )Total γ branch ratio (number of emitted photons per decay)Detection efficiency []Activity concentration in the coolant in the exit of helium purification system (99.9% purification efficiency)
(Bq·L–1)

Kr-85m2.674E – 040.8926701.848E – 0460.001.11E – 02
Kr-874.102E – 040.7796752.476E – 0467.001.66E – 02
Kr-884.302E – 041.2392454.127E – 04140.005.78E – 02
Kr-894.050E – 041.2729803.991E – 0420.007.98E – 03
Xe-1332.738E – 040.0007121.509E – 07850.001.28E – 04
Xe-133m3.194E – 040.1030002.547E – 0528.007.13E – 04
Xe-1353.312E – 040.9279482.379E – 04130.003.09E – 02
Xe-135m3.760E – 040.8099702.358E – 0414.003.30E – 03
Xe-1373.700E – 040.3201509.170E – 0542.003.85E – 03
Xe-1383.948E – 041.1336393.465E – 0493.003.22E – 02
I-1313.536E – 040.9628912.636E – 040.184.74E – 05
I-1324.040E – 042.8708468.978E – 042.302.06E – 03
I-1333.804E – 040.9915572.920E – 040.922.69E – 04
I-1344.084E – 042.8859589.124E – 044.704.29E – 03
I-1354.344E – 041.2141364.083E – 041.405.72E – 04
Rb-884.488E – 040.3739611.299E – 047.701.00E – 03
Cs-1383.616E – 041.8723625.241E – 041.608.39E – 04

1.19E – 04