Research Article

Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM

Table 5

Calculation of the detection efficiency of the online monitoring system in the characteristic spectrum interval of Kr-88 (785–885 keV).

NuclidesAverage pulses emitted by the detector in the characteristic spectrum interval of Kr-88  (785–885 keV)
(count/particle)
Total γ branch ratio I (number of emitted photons per decay)Detection efficiency []Specific activity in the coolant at the exit of the HPS (99.9% purification efficiency)
( Bq·L–1)

Kr-85m0.00E + 000.8926700.00E + 0060.000.00E + 00
Kr-877.00E – 060.7796754.22E – 0667.002.83E – 04
Kr-881.28E – 051.2392451.23E – 05140.001.72E – 03
Kr-897.20E – 061.2729807.09E – 0620.001.42E – 04
Xe-1330.00E + 000.0007120.00E + 00850.000.00E + 00
Xe-133m0.00E + 000.1030000.00E + 0028.000.00E + 00
Xe-1350.00E + 000.9279480.00E + 00130.000.00E + 00
Xe-135m0.00E + 000.8099700.00E + 0014.000.00E + 00
Xe-1372.00E – 070.3201504.96E – 0842.002.08E – 06
Xe-1382.60E – 061.1336392.28E – 0693.002.12E – 04
I-1310.00E + 000.9628910.00E + 000.180.00E + 00
I-1323.00E – 062.8708466.67E – 062.301.53E – 05
I-1335.80E – 060.9915574.45E – 060.924.10E – 06
I-1343.16E – 052.8859587.06E – 054.703.32E – 04
I-1351.52E – 051.2141361.43E – 051.402.00E – 05
Rb-887.00E – 060.3739612.03E – 067.701.56E – 05
Cs-1380.00E + 001.8723620.00E + 001.600.00E + 00

1.88E – 06