Research Article

Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM

Table 6

Changes in and due to increasing or decreasing the activity concentrations of some nuclides by one order of magnitude.

Relative rate of change
(%)
Relative rate of change
(%)
[][]

Original activity concentration1.19E – 040.01.88E – 060.0

Kr-88Increase its activity concentration by one order of magnitude2.55E – 04114.36.69E – 06255.9
Decrease its activity concentration by one order of magnitude9.10E – 05–23.58.96E – 07–52.3

Xe-133Increase its activity concentration by one order of magnitude1.92E – 05–83.93.01E – 07–84.0
Decrease its activity concentration by one order of magnitude2.49E – 04109.23.93E – 06109.0

Xe-135Increase its activity concentration by one order of magnitude1.72E – 0444.51.04E – 06–44.7
Decrease its activity concentration by one order of magnitude1.08E – 04–9.22.04E – 068.5

I-131Increase its activity concentration by one order of magnitude1.19E – 040.01.87E – 06–0.5
Decrease its activity concentration by one order of magnitude1.19E – 040.01.88E – 060.0