Research Article
Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM
Table 6
Changes in
and
due to increasing or decreasing the activity concentrations of some nuclides by one order of magnitude.
| | | Relative rate of change (%) | | Relative rate of change (%) | [] | [] |
| Original activity concentration | 1.19E – 04 | 0.0 | 1.88E – 06 | 0.0 |
| Kr-88 | Increase its activity concentration by one order of magnitude | 2.55E – 04 | 114.3 | 6.69E – 06 | 255.9 | Decrease its activity concentration by one order of magnitude | 9.10E – 05 | –23.5 | 8.96E – 07 | –52.3 |
| Xe-133 | Increase its activity concentration by one order of magnitude | 1.92E – 05 | –83.9 | 3.01E – 07 | –84.0 | Decrease its activity concentration by one order of magnitude | 2.49E – 04 | 109.2 | 3.93E – 06 | 109.0 |
| Xe-135 | Increase its activity concentration by one order of magnitude | 1.72E – 04 | 44.5 | 1.04E – 06 | –44.7 | Decrease its activity concentration by one order of magnitude | 1.08E – 04 | –9.2 | 2.04E – 06 | 8.5 |
| I-131 | Increase its activity concentration by one order of magnitude | 1.19E – 04 | 0.0 | 1.87E – 06 | –0.5 | Decrease its activity concentration by one order of magnitude | 1.19E – 04 | 0.0 | 1.88E – 06 | 0.0 |
|
|