Design of the Online Gross γ Monitoring Instrument at the Exit of the Helium Purification System in HTR-PM
Table 7
Detection efficiency of Kr-88 and Xe-135 for different NaI(Tl) crystal sizes and distances between crystal and pipe.
| Size of the NaI crystal | Φ80 mm × 50 mm | Φ60 mm × 50 mm | Φ50 mm × 50 mm | Φ50 mm × 50 mm | Φ50 mm × 50 mm |
| Distance between the NaI crystal center and pipe center [cm] | 35.15 | 35.15 | 35.15 | 30.15 | 20.15 |
| Kr-88 | [count/particle] | 1.02E – 03 | 6.00E – 04 | 4.30E – 04 | 6.33E – 04 | 1.82E – 03 | [count/particle] | 3.46E – 05 | 1.92E – 05 | 1.28E – 05 | 1.80E – 05 | 4.16E – 05 |
| Xe-135 | [count/particle] | 7.99E – 04 | 3.31E – 04 | 4.64E – 04 | 4.89E – 04 | 1.38E – 03 | [count/particle] | 0 | 0 | 0 | 0 | 0 |
|
|