Research Article
Development and Verification of a Transient Analysis Tool for Reactor System Using Supercritical CO2 Brayton Cycle as Power Conversion System
Table 3
Details of the experimental conditions.
| TEST NO. | | | | | | |
| | MPa | Kg/hr | °C | °C | kg/hr | °C |
| B6 | 8.003 | 100.53 | 88.63 | 36.07 | 701.59 | 35.63 |
| B7 | 8.001 | 200.77 | 88.10 | 35.98 | 699.78 | 35.11 |
| B8 | 7.972 | 297.14 | 89.36 | 36.20 | 701.8 | 35.05 |
| B9 | 8.003 | 401.01 | 87.92 | 36.05 | 701.77 | 33.28 |
| B10 | 7.995 | 500.61 | 87.93 | 35.90 | 700.09 | 31.28 |
| B11 | 8.003 | 100.03 | 87.68 | 37.94 | 697.80 | 37.68 |
| B12 | 8.005 | 199.73 | 88.85 | 37.97 | 697.80 | 37.53 |
| B13 | 7.998 | 301.31 | 88.17 | 38.03 | 699.86 | 37.48 |
| B14 | 8.020 | 404.29 | 88.97 | 38.29 | 701.62 | 37.58 |
| B15 | 7.998 | 501.79 | 88.09 | 38.01 | 702.25 | 36.83 |
|
|