Research Article

Development and Verification of a Transient Analysis Tool for Reactor System Using Supercritical CO2 Brayton Cycle as Power Conversion System

Table 4

Experiment data from SCO2PE and predicted result from SCTRAN/CO2 and GAMMA+ on the compressor outlet temperature.

Experiment(SCO2PE data)GAMMASCTRAN/CO2

Compressor outlet temperature/°Ccase 138.342.2(+3.9)40.55(+2.25)
case 245.846.5(+0.7)46.67(+0.87)

Compressor outlet pressure/MPacase 18.658.658.65
case 29.129.129.15

compressor efficiencycase 158.658.658.6
case 236.136.136.1