Research Article

ROSA/LSTF Tests and Posttest Analyses by RELAP5 Code for Accident Management Measures during PWR Station Blackout Transient with Loss of Primary Coolant and Gas Inflow

Figure 7

TR-LF-18 test and RELAP5 results for SG secondary-side collapsed liquid level in loop A.