Research Article

ROSA/LSTF Tests and Posttest Analyses by RELAP5 Code for Accident Management Measures during PWR Station Blackout Transient with Loss of Primary Coolant and Gas Inflow

Table 2

Details of LSTF U-tubes in each SG.

TypeStraight length (m)Number of tubesInstrumented tubes

19.4421Two short tubes
29.5919
39.7419
49.8919
510.0417Two medium tubes
610.1915
710.3413
810.4911
910.647Two long tubes