Research Article
Study of Fast Transient Pressure Drop in VVER-1000 Nuclear Reactor Using Acoustic Phenomenon
Table 3
Relative power radial distribution in 1/6 of VVER-1000 reactor core.
| Fuel assembly number | Power peaking factor (FSAR) [18] | Power peaking factor (DRAGON 4/DONJON 4) | Power peaking factor (WIMS/CITATION) [19] |
| 1 | 1.01 | 1.02 | 0.99 | 2 | 0.80 | 0.79 | 0.78 | 3 | 1.02 | 1.01 | 1.00 | 4 | 0.75 | 0.75 | 0.72 | 5 | 0.86 | 0.85 | 0.83 | 6 | 0.92 | 0.89 | 0.90 | 7 | 1.16 | 1.17 | 1.18 | 8 | 0.92 | 0.93 | 0.90 | 9 | 0.78 | 0.78 | 0.76 | 10 | 0.87 | 0.88 | 0.84 | 11 | 0.86 | 0.85 | 0.84 | 12 | 1.24 | 1.22 | 1.24 | 13 | 0.96 | 0.97 | 0.98 | 14 | 0.78 | 0.77 | 0.76 | 15 | 1.03 | 1.04 | 1.02 | 16 | 0.89 | 0.88 | 0.87 | 17 | 1.11 | 1.10 | 1.11 | 18 | 1.18 | 1.17 | 1.24 | 19 | 0.87 | 0.86 | 0.84 | 20 | 0.89 | 0.87 | 0.87 | 21 | 1.29 | 1.27 | 1.31 | 22 | 1.24 | 1.25 | 1.31 | 23 | 0.86 | 0.85 | 0.84 | 24 | 1.11 | 1.09 | 1.11 | 25 | 1.24 | 1.23 | 1.31 | 26 | 1.24 | 1.22 | 1.24 | 27 | 1.18 | 1.17 | 1.24 | 28 | 0.96 | 0.96 | 0.98 |
|
|