Table 1

The coefficient ā€œā€ of (5) for subcooled CHF.

Result/Model

Plain Cu (Present)0.0535
HTCMC (Present)0.0296
Kutateladze [1]0.0446
Ivey and Morris [3]0.0482
Zuber [6]0.0522