Research Article
ASTEC–MAAP Comparison of a 2 Inch Cold Leg LOCA until RPV Failure
Table 2
Key automatic and operator actions.
| EVENT | CONDITION |
| Reactor trip | Pressurizer pressure falls below 131 bar |
| Isolation of accumulators | Primary pressure falls below 15 bar |
| Steam generator regulation to 33% (narrow range) | t = t(Safety Injection Actuation) |
| Reactor coolant pump trip | Pressurizer pressure falls below 118 bar |
| Safety injection actuation | Pressurizer pressure falls below 119 bar |
| Containment sprays actuation | Containment pressure rises above 2.4 bar |
|
|