Research Article

ASTEC–MAAP Comparison of a 2 Inch Cold Leg LOCA until RPV Failure

Table 2

Key automatic and operator actions.

EVENTCONDITION

Reactor tripPressurizer pressure falls below 131 bar

Isolation of accumulatorsPrimary pressure falls below 15 bar

Steam generator regulation to 33% (narrow range)t = t(Safety Injection Actuation)

Reactor coolant pump tripPressurizer pressure falls below 118 bar

Safety injection actuationPressurizer pressure falls below 119 bar

Containment sprays actuationContainment pressure rises above 2.4 bar