Research Article
ASTEC–MAAP Comparison of a 2 Inch Cold Leg LOCA until RPV Failure
Table 5
Key results in the SBLOCA predicted by ASTEC and MAAP.
| Event | ASTEC_REF | MAAP_REF | ASTEC_SEN | MAAP_SEN |
| Integrated liquid break mass at 200 seconds | 26600 kg | 21900 kg | 26600 kg | 21900 kg |
| Integrated liquid break mass at 1e4 seconds | 143395 kg | 120830 kg | 136593 kg | 120830 kg |
| Integrated gas break mass at 1e4 seconds | 68800 kg | 71924 kg | 80188 kg | 66775 kg |
| Primary pressure at 1500 seconds | 7.3e6 Pa | 7.2e6 Pa | 7.3e6 Pa | 7.2e6 Pa |
| Primary pressure at 1e4 seconds | 1.0e6 Pa | 2.2e6 Pa | 1.9e6 Pa | 1.1e6 Pa |
| Accumulator discharged mass | 44.16 tons | 66.94 tons | 68.26 tons | 44.16 tons |
| In-vessel hydrogen generation | 528 kg | 605 kg | 586 kg | 502 kg |
| Total relocated mass | 167 tons | 127 tons | 147 tons | 127 tons |
| Highest slumping rate | 15100 kg/s | 788 kg/s | 13100 kg/s | 607 kg/s |
| Maximum corium pool temperatures | 2760 K | 2850 K | 2665 K | 2850 K |
| Lower head wall location | 0.4 m below cylinder | 0.55 m below cylinder | 0.55 m below cylinder | 0.55 m below |
| Type of RPV failure | Creep rupture by focusing effect | Creep rupture | Creep rupture by focusing effect | Creep rupture |
|
|