Research Article

Validation of the COTENP Code: A Steady-State Thermal-Hydraulic Analysis Code for Nuclear Reactors with Plate Type Fuel Assemblies

Table 3

IFA power, coolant velocity, and IFA pressure drop at different power levels of the IEA-R1 . The IFA is located at the (6,8) position.

ā€‰Power level = 4 MWPower level = 4.5 MWPower level = 5 MW
ā€‰ExperimentalCOTENPDiscrepancy (%)ExperimentalCOTENPDiscrepancy (%)ExperimentalCOTENPDiscrepancy (%)

IFA Power (kW)147.61143.402.9162.39158.262.6177.53154.2913.2
Coolant velocity (m/s)1.9201.9461.41.9201.9481.51.9201.9491.5
Pressure drop (kPa)7.8357.0010.77.8357.010.77.8357.010.7

experimental errors were not reported.