Research Article

Experimental Investigation of Decontamination Factor Dependence on Aerosol Concentration in Pool Scrubbing

Table 3

Aerosol measurement information of the experiments PF1 and PF2.

ExperimentAveraged number concentration at outlet (1/m3)Waiting time (s)Measurement time (s)Number of measurements (-)

PF12.1×101030018001
3.6×1010900
6.5×1010510
1.0×1011360
3.6×10911100

PF27.7×10930045301
3.4×1010960
1.1×1011300
7.8×1010420

Condition was set in the order from the top.
Longer than this as an experimental protocol but no specific data for each condition.