Value of temperature in the calculation point of the model.
| Filler | The thickness of the concrete, m | Power of FA, W | Maximal temperature of FA, K | Temperature values in points, K | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
| argon | 0.5 | 120 | 553 | 293 | 396 | 501 | 450 | 466 | 493 | 503 | 493 | 466 | 552 | 0.5 | 190 | 682 | 293 | 460 | 613 | 538 | 562 | 601 | 615 | 601 | 562 | 679 | 1.0 | 120 | 594 | 293 | 440 | 546 | 496 | 512 | 538 | 547 | 538 | 512 | 593 | 1.0 | 190 | 745 | 293 | 531 | 682 | 610 | 633 | 670 | 684 | 670 | 633 | 743 |
| air | 0.5 | 120 | 516 | 293 | 395 | 481 | 434 | 449 | 473 | 482 | 473 | 449 | 513 | 0.5 | 190 | 627 | 293 | 455 | 582 | 513 | 534 | 571 | 584 | 571 | 534 | 624 | 1.0 | 120 | 557 | 293 | 440 | 525 | 480 | 493 | 518 | 527 | 518 | 493 | 554 | 1.0 | 190 | 692 | 293 | 527 | 651 | 585 | 606 | 640 | 653 | 640 | 606 | 689 |
|
|