Prediction error of the present mechanistic model.
| Data points | Maximum error | Minimum error | The fraction of error within 10% | The fraction of error within 20% | ME | RMS |
| The whole experiment database |
| 4355 | 44.2% | -38.9% | 82.2% | 96.0% | 0.5% | 8.3% |
| The DNB type CHF |
| 2735 | 44.5% | -46.0% | 85.8% | 96.4% | 0.6% | 7.0% |
|
|