Research Article

The Study of Critical Heat Flux in Upflow Boiling Vertical Round Tube under High Pressure

Table 6

Prediction results of three different entrainment and deposition correlations.

Data pointsDifferent correlationMaximum errorMinimum errorThe fraction of error within 10%The fraction of error within 20%MERMS

1620Kataoka34.7%-38.9%72.1%94.5%0.4%9.9%
Celata40.3%-61.3%36.2%49.0%27.9%40.1%
Hewitt14.4%-86.1%2.9%15.8%40.6%45.0%