Science and Technology of Nuclear Installations / 2019 / Article / Tab 8

Research Article

Validation of Modified ART Mod 2 Code through Comparison with Aerosol Deposition of Cesium Compound in Phébus FPT3 Containment Vessel

Table 8

Design conditions of containment vessel, dry condenser, and wet condenser in ART Mod 2.

Design conditionsContainment vessel volumeDry condenser part volumeWet condenser part volume

Diameter [m]1.770.900.90
Height [m]4.070.711.64
Total Area [m2]27.521.012.32
Total Volume [m3]102.014.65