Research Article

Standalone Containment Analysis of Four Phébus Tests with the ASTEC and the MELCOR Codes

Table 4

Amount of FP and SM flowing into the CV during the Phébus FPT tests.

Mass [g]
ElementFPT-0FPT-1FPT-2FPT-3

Xe0.02822.932.3725.43

Kr0.2632.142.6281.924

Te0.0371.331.0570.116

I0.0230.7180.8830.387

Sb6.4e-40.02

Cs0.0746.959.1823.757

Sn10.116.13.3411.618

Cd5.615.26.808

Co3.6

Ag50327.1090.031

In7.475.119

W20.6761.012

Re2729.41.4280.0724

Mn4

Ru2.7e-40.0560.0130.03

Cr0.77

Ba8.9e-40.0650.0530.068

U6.910.90.2470.065

Sr2.1e-50.0170.0320.016

Nb3.5e-7

Zr2.4e-50.50.2680.05

Sm9.6e-4

Nd9.e-4

Np0.013

Pu0.9

Al1.9

Pb1

Mo4.67.2351.655

Tc10.0650.016

Rb1.21.1270.464

Ce0.04

Y0.003

La0.006

Pm0.002

B1.331

Total117.8155.976.738.0