Research Article

Multilayer Shielding Design for Intermediate Radioactive Waste Storage Drums: A Comparative Study between FLUKA and QAD-CGA

Table 4

Comparison of the calculation cost and efficiency of FLUKA.

ā€‰Total timeAverage CPU time for a primary particleTotal number of particlesParallel numberFOM factor (1/s)

Case 14.625 h1.67E-04s1E810.62%1.56

Case 225.5 h1.84E-04s5E810.33%1.00

Case 35 d2.16E-031.00E+0950.44%0.024

Case 4a9 d3.70E-031.80E+0990.53%0.005

Case 4b25.6 h9.23E-041.00E+0810.98%0.11

a: direct calculation.
b: optimized setting and VRT adopted.
c here gives the maximum statistical relative error of the dose calculation matrix.