Journals
Publish with us
Publishing partnerships
About us
Blog
Science and Technology of Nuclear Installations
Journal overview
For authors
For reviewers
For editors
Table of Contents
Special Issues
Science and Technology of Nuclear Installations
/
2020
/
Article
/
Tab 3
/
Research Article
Numerical Investigation of Water Film Evaporation with the Countercurrent Air in the Asymmetric Heating Rectangular Channel for Passive Containment Cooling System
Table 3
Grid independence analysis for the Eulerian_ EWF method.
Total number of grid cells
640,000
960,000
1,440,000
2,160,000
(kW)
102.90
91.40
90.97
90.77
,
(kg/s)
0.04070
0.03573
0.03562
0.03553
T
l
,ave
(K)
348.98
347.21
347.34
347.31
T
f
(K)
322.40
321.02
321.79
321.77