Research Article

Integrated Security System (ISS) Design and Evaluation for Commercial Nuclear Power Plant

Table 1

Response force delay time RFT for scenario 1.1.

Guards delay timeSecResponse force delay timeSec

Alarm communication time1Alarm communication time1
Alarm assessment time45Alarm assessment time45
Communication time to guards25Communication time to guards25
Guards preparation time15Response force preparation time90
Guards travel and deployment time34Response force travel time (by vehicles)120
On-site deployment time (after travel)75
120Total RFT = 356