Research Article
An Efficient Scheme for Coupling OpenMC and FLUENT with Adaptive Load Balancing
Table 3
Comparison of the single PWR cell model results.
| | Keff | Peak clad temperature | Temperature rise of coolant |
| Results in reference [7] | 0.6601 ± 0.0009 | 720.1 K at 10.9 cm | 11.0 K | Results in this paper | 0.6602 ± 0.0003 | 720.0 K at 10.9 cm | 10.9 K |
|
|