Research Article

An Efficient Scheme for Coupling OpenMC and FLUENT with Adaptive Load Balancing

Table 3

Comparison of the single PWR cell model results.

KeffPeak clad temperatureTemperature rise of coolant

Results in reference [7]0.6601 ± 0.0009720.1 K at 10.9 cm11.0 K
Results in this paper0.6602 ± 0.0003720.0 K at 10.9 cm10.9 K