Research Article
Development of Fuel Product Barrier Monitoring System Based on State Functions in State-Oriented Emergency Operating Procedure
| State functions | Safety functions | Parameters |
| Subcriticality (S/K) | Reactivity | Intermediate range detector (IRD) | Residual heat removal [WR (P, T)] | Core cooling | RCS pressure (P RCS), subcooling margin (ΔTsat), and temperature at core outlet (T RIC) | Primary water inventory (IEP) | | Reactor pressure vessel water level (RPVL) | Secondary water inventory (IES) | | SG water level wide range (L SG WR) | Secondary integrity (INTS) | Containment | Steam line pressure and SG activity channels | Containment integrity (INTE) | | Containment pressure (Pcont) and containment dose rate (DRcont) |
|
|