Research Article

Development of Fuel Product Barrier Monitoring System Based on State Functions in State-Oriented Emergency Operating Procedure

Table 2

Sequence and result of station blackout.

Time (h)Sequence of transientFPB status displayed on FPBMS

0Reactor trip
1.6Exhaustion of water inventory in SGs
2.0Core is beginning to uncover
2.1Pcont is over 0.24 MPa
2.5T RIC is over 650°C