Research Article

Shielding Design and Dose Evaluation for HTR-PM Fuel Transport Pipelines by QAD-CGA Program

Table 3

and D40y at Dpi = 30 cm for 1–5 m pipelines for the average burn-up fuel source term.

Pipeline lengths (m) (mGy/h)D40y (Gy)
No shielding4.5 cm lead5 cm leadNo shielding4.5 cm lead5 cm lead

13713.492.491.30 × 1051220871
24673.662.591.64 × 1051280907
34983.662.591.75 × 1051280908
45113.662.591.79 × 1051280908
55183.662.591.82 × 1051280908