Research Article

Neutronic Performance of the VVER-1000 Reactor Using Thorium Fuel with ENDF Library

Table 4

Comparison between current calculated parameters with references [9, 19, 20].

Data sourceDC (1/oC)MTC (1/oC)βeff

UO2-7 (current results for UO2by ENDF/B-VII)−2.88 × 10−5−1.39 × 10−40.0078
UO2-8 (current results for UO2by ENDF/B-VIII)−2.61 × 10–5−1.13 × 10–40.00688
MCNPX 2.6, ENDF/B-VI [20]0.00711
WIMSD4 [9]−2.04 × 10−5−1.15 × 10−4
Reactor design [19]−2.11 × 10−5−1.30 × 10−40.00740
UTh-7 (current results for UO2+ThO2 by ENDF/B-VII)−2.54 × 10−5−0.339 × 10−40.00628
UTh-8 (current results for UO2+ThO2 by ENDF/B-VIII)−3.055 × 10−5−0.416 × 10−40.00545