Analysis and Estimation of Core Damage Frequency of Flow Blockage and Loss of Coolant Accident: A Case Study of a 10 MW Water-Water Research Reactor-PSA Level 1
Table 3
System fault tree with the top event “no pool isolation”.
Basic event
Components failure identification
Probability
1
Operator fails to close manual butterfly valves
1.000 × 10−2
2
Manual butterfly valves fail in an open position
3.600 × 10−6
3
Operator fails to give a signal to pneumatic valves