COMSOL Simulation for Design of Induction Heating System in VULCAN Facility

Table 2

Comparison of measured and simulated temperatures.

Current of inductor (A)Measured (K)Simulated (K)Absolute deviation (K)Relative deviation

40.3343.9338.6−5.3−1.5%
59.8402.1395.5−6.6−1.6%
81.1497.4475.1−22.3−4.5%
99.7612.7577.4−35.3−5.8%
200.01509.81431.4−78.4−5.2%
251.3a2364.1a

aThe experiment of 300 A was not carried out because the predicted temperature under this condition is close to the melting point of graphite.