Research Article

Verification of the Efficacy of Passive Autocatalytic Recombiners in a Typical Pressurized Water Reactor under a Station Blackout Condition

Table 1

PAR characteristic for SKN units 3 and 4.

CompanyKorea Nuclear Technology (KNT)

TypeCatalytic
Quantity (for each unit)(i) Large: 16 (including 8 PARs for DBA)
(ii) Medium: 10 (including 8 PARs for DBA)
(iii) Small: 4
Recombination rate (g/sec)(i) Large: 0.9 at 4.0 v/o H2, 2.0 at 8.0 v/o H2
(ii) Medium: 0.4 at 4.0 v/o H2, 1.0 at 8.0 v/o H2
(iii) Small: 0.2 at 4.0 v/o H2, 0.5 at 8.0 v/o H2
Operable hydrogen concentration(i) Above 2.0 v/o (initial)
(ii) Above 0.5 v/o (continuous)
Material(i) Housing: stainless steel
(ii) Catalyst: Al2O3 + Pt coating