Effect of MAAP parameters (phenomenological uncertainty).

ParameterRangeDefaultValueH2 mass (kg)Variation (%)Case#

LMCOL0
LMCOL1
LMCOL2
LMCOL3
48.0∼54.05348448.34−5.91
50460.70−3.32
52473.49−0.63
54475.91−0.14
EPSCUT0.0∼0.250.10486.972.35
0.08491.603.26
0.16481.561.17
0.25479.670.78
0.02495.614.19
0.04480.40.910
0.06490.793.111
TCLMAX100∼3000 K2500 K2000341.06−28.412
2250368.97−22.513
2750516.778.514
3000498.084.615
FAOX1.0∼2.01.01.25438.4−7.916
1.5476.250.017
1.75489.362.818
2482.481.319
FGBYPA0∼110462.74−2.820
0.25462.74−2.821
0.5476.250.022
0.75476.250.023
TAUTO750∼1200 K983 K750476.250.024
900476.250.025
1050476.250.026
1200476.250.027
TJBRN900∼1900 K1060 K900480.91.028
1233469.7−1.429
1566471.4−1.030
1900471.4−1.031
DXHIG−0.04∼10.0−0.04476.250.032
0.31476.250.033
0.65476.250.034
1476.250.035
ENT00.025∼0.0600.0450.04475.66−0.136
0.045476.250.037
0.05476.710.138
EPSCU20.001∼0.350.20.15470.17−1.339
0.2476.250.040
0.25479.670.741
0.3473.74−0.542
FZORUP0.0∼1.00.70.6476.250.043
0.65476.250.044
0.7476.250.045
0.75476.250.046
0.8476.250.047