Research Article
Verification of the Efficacy of Passive Autocatalytic Recombiners in a Typical Pressurized Water Reactor under a Station Blackout Condition
Table 13
Results of sensitivity study #5 (MAAP parameter, base case).
| Depressurization time (sec) | EPSCUT | TCLMAX | FAOX | H2 mass (kg) | Case# |
| 10,850 | 0.02 | 2750 | Default | 510.61 | 1 | Default | 2750 | 1.75 | 536.07 | 2 | 0.02 | Default | 1.75 | 470.64 | 3 | 0.02 | 2750 | 1.75 | 534.46 | 4 | 10,900 | 0.02 | 2750 | Default | 506.83 | 5 | Default | 2750 | 1.75 | 523.21 | 6 | 0.02 | Default | 1.75 | 461.72 | 7 | 0.02 | 2750 | 1.75 | 544.95 | 8 | 10,925 | 0.02 | 2750 | Default | 504.37 | 9 | Default | 2750 | 1.75 | 543.33 | 10 | 0.02 | Default | 1.75 | 459.92 | 11 | 0.02 | 2750 | 1.75 | 537.39 | 12 | 10,950 | 0.02 | 2750 | Default | 531.90 | 13 | Default | 2750 | 1.75 | 530.30 | 14 | 0.02 | Default | 1.75 | 457.29 | 15 | 0.02 | 2750 | 1.75 | 516.91 | 16 | 11,000 | 0.02 | 2750 | Default | 526.41 | 17 | Default | 2750 | 1.75 | 519.92 | 18 | 0.02 | Default | 1.75 | 457.41 | 19 | 0.02 | 2750 | 1.75 | 538.36 | 20 | 11,050 | 0.02 | 2750 | Default | 527.34 | 21 | Default | 2750 | 1.75 | 531.24 | 22 | 0.02 | Default | 1.75 | 461.05 | 23 | 0.02 | 2750 | 1.75 | 543.11 | 24 |
|
|
The bold values point to the case with maximum hydrogen production.
|