Research Article

Verification of the Efficacy of Passive Autocatalytic Recombiners in a Typical Pressurized Water Reactor under a Station Blackout Condition

Table 14

Result of sensitivity study #6 (base case without external injection).

Depressurization time (sec)EPSCUTTCLMAXFAOXH2 mass (kg)Oxidation (%)Case#

985027501.75492.4455.571
0.0227501.75487.4155.002
10,35027501.75517.6358.413
0.0227501.75522.3158.944
10,85027501.75546.5761.685
0.0227501.75544.7961.476
10,90027501.75549.1461.977
0.0227501.75525.3859.288
10,92527501.75543.0261.279
0.0227501.75534.9360.3610
10,95027501.75525.5759.3111
0.0227501.75529.859.7812
11,00027501.75529.6159.7613
0.0227501.75551.9362.2814
11,25027501.75528.9559.6915
0.0227501.75540.8761.0316
11,50027501.75513.8557.9817
0.0227501.75523.959.1218
11,75027501.75493.8555.7319
0.0227501.75504.8859.9720
12,00027501.75495.5555.9221
0.0227501.75504.8456.9722
12,50027501.75493.655.7023
0.0227501.75504.8756.9724
13,00027501.75493.7155.7125
0.0227501.75504.8656.9726

The bold values point to the case with maximum hydrogen production.