Research Article

Verification of the Efficacy of Passive Autocatalytic Recombiners in a Typical Pressurized Water Reactor under a Station Blackout Condition

Table 15

Time and temperature distribution due to core damage.

Core damage (%)TimeTCRHOTTCLN (10)TCLN (11)TCLN (12)

210,712.072904.631188.901212.611240.69
511,022.862791.102947.342910.902802.80
1011,063.002852.932873.682911.002911.00
2011,103.053215.812795.752826.262832.83
5011,113.063183.192787.102819.452876.16
6011,133.093132.792768.052802.112687.49
7011,263.133100.052870.402758.782854.08
8011,604.113118.262911.002872.662860.10
9021,259.883121.04100.00100.00100.00

TCRHOT: maximum core temperature; TCLN (i): clad temperature in node i.