Verification of the Efficacy of Passive Autocatalytic Recombiners in a Typical Pressurized Water Reactor under a Station Blackout Condition

Table 16

Result of sensitivity study #7 (timing and flow rate of external injection).

Flow rateTime (sec)Core damage (%)H2 mass (kg)Oxidation (%)Case#

5 kg/s11,010537.5960.891
10,7122547.9661.832
11,0225539.1160.833
11,10320549.8862.054
11,11350532.8760.135
11,13360532.3960.076
11,26370557.6662.937
11,60480542.8661.268
10 kg/s11,010526.1659.379
10,7122455.0551.3510
11,0225531.8260.0011
11,10320671.1975.7412
11,11350531.1759.9413
11,13360537.0960.6014
11,26370530.2459.8315
11,60480544.161.4016
16 kg/s11,010695.5578.4917
10,7122449.0050.6618
11,0225700.3779.0319
11,10320520.6658.7520
11,11350740.0483.5121
11,13360519.9058.6722
11,26370535.7960.4623
11,60480650.9173.4524
20 kg/s11,010535.0360.3725
10,7122437.5349.3726
11,0225520.5958.7427
11,10320522.9459.0128
11,11350511.5157.7229
11,13360650.0673.3530
11,26370745.1084.0831
11,60480655.7573.9932
32 kg/s11,010537.2260.6233
10,7122135.4715.2934
11,0225528.0859.5935
11,10320538.9560.8136
11,11350502.8656.7437
11,13360503.4656.8138
11,26370522.4558.9539
11,60480653.3073.7240