Research Article

Verification of the Efficacy of Passive Autocatalytic Recombiners in a Typical Pressurized Water Reactor under a Station Blackout Condition

Table 5

List of MAAP parameters reviewed in the sensitivity study.

ParameterRangeDefaultDescription

LMCOL0
LMCOL1
LMCOL2
LMCOL3
48.0∼54.053(i) Collapse criterion parameters for a Larson–Miller-like functional dependence
EPSCUT0.0∼0.250.1(ii) Cutoff porosity below which the flow area and the hydraulic diameter of a core node are zero
TCLMAX100∼3000 K2500 K(iii) Temperature that will lead to cladding rupture
FAOX1.0∼2.01.0(iv) Multiplier for the cladding outside surface area
FGBYPA0∼11(v) Flag to divert gas flows in the core to the bypass channel
TAUTO750∼1200 K983 K(vi)Autoignition temperature for hydrogen and carbon monoxide burns
TJBRN900∼1900 K1060 K(vii) Temperature of a H2 jet entering a noninserted compartment which is sufficient to cause a local burn
DXHIG−0.04∼10.0(viii) Offset H2 and CO mole fraction for ignition of a flammable mixture
ENT00.025∼0.0600.045(ix) Jet entrainment coefficient for the Ricou–Spalding correlation
EPSCU20.001∼0.350.2(x) Cutoff porosity below which the flow area and the hydraulic diameter of a collapsed core node
FZORUP0.0∼1.00.7(xi) Minimum fraction of Zr that must be oxidized to keep the cladding intact if the cladding is at TCLMAX