List of MAAP parameters reviewed in the sensitivity study.
| Parameter | Range | Default | Description |
| LMCOL0 LMCOL1 LMCOL2 LMCOL3 | 48.0∼54.0 | 53 | (i) Collapse criterion parameters for a Larson–Miller-like functional dependence | EPSCUT | 0.0∼0.25 | 0.1 | (ii) Cutoff porosity below which the flow area and the hydraulic diameter of a core node are zero | TCLMAX | 100∼3000 K | 2500 K | (iii) Temperature that will lead to cladding rupture | FAOX | 1.0∼2.0 | 1.0 | (iv) Multiplier for the cladding outside surface area | FGBYPA | 0∼1 | 1 | (v) Flag to divert gas flows in the core to the bypass channel | TAUTO | 750∼1200 K | 983 K | (vi)Autoignition temperature for hydrogen and carbon monoxide burns | TJBRN | 900∼1900 K | 1060 K | (vii) Temperature of a H2 jet entering a noninserted compartment which is sufficient to cause a local burn | DXHIG | −0.04∼1 | 0.0 | (viii) Offset H2 and CO mole fraction for ignition of a flammable mixture | ENT0 | 0.025∼0.060 | 0.045 | (ix) Jet entrainment coefficient for the Ricou–Spalding correlation | EPSCU2 | 0.001∼0.35 | 0.2 | (x) Cutoff porosity below which the flow area and the hydraulic diameter of a collapsed core node | FZORUP | 0.0∼1.0 | 0.7 | (xi) Minimum fraction of Zr that must be oxidized to keep the cladding intact if the cladding is at TCLMAX |
|
|