Research Article

Verification of the Efficacy of Passive Autocatalytic Recombiners in a Typical Pressurized Water Reactor under a Station Blackout Condition

Table 6

Key MAAP parameters impacting H2 generation.

ParameterMINMAXDefaultUsed

FAOX1.02.01.01.75
TCLMAX (K)100300025002750