Research Article

Development and Testing of TRACE/PARCS ECI Capability for Modelling CANDU Reactors with Reactor Regulating System Response

Table 3

Event timings compared to station data and previous studies.

EventStation data (s)[18] (s)This work (s)

Loss of class IV power000
Turbine trip000
Emergency stop valve (ESV) closeNo data0.280.28
Stepback on turbine trip0.50.50.5
CSDV open0.80.80.8
ASDV open1.013.613.5
SDS1 low flow trip2.93.33.41
Liquid relief valve (LRV) open3.54.2Not actuated
SDS2 low flow trip11.6N/AN/A

1This is the timing of when the trip condition is met—shutdown rod actuation is delayed by an additional 0.3 seconds.