Research Article

Experimental Study of Onset of Nucleate Boiling in Vertical Rectangular Channels with Different Flow Path Heights

Table 2

Parameters and experimental range of two test sections.

Channel aChannel b
Size (mm)1.8 × 60.0 × 610.02.8 × 60.0 × 610.0
Hydraulic diameter, (mm)3.505.35
Pressure, p (MPa)0.1450.145
Mass flux, G (kg/(m2·s))100, 200, and 300100, 200, and 300
Inlet temperature, (°C)70–10070–100
Heat flux, q (kW/m2)10–7010–70