Research Article
Assessing the Impact of Common Cause Failures on Site Risk within Level 1 Multi-Unit PSA
Table 3
Major CCF events in the multi-unit LOOP event.
| No. | Event | Description | FV | #MCS |
| 1 | EPDGW-DGAB | DGs A and B fail to start and load due to CCF | 0.022490 | 6 | 2 | 2-EPDGW-DGCD | DGs C and D fail to start and load due to CCF | 0.022490 | 6 | 3 | EPDGW-CCF-DG-A-AAC | Loss of power from DG A and AACDG due to inter-unit CCF | 0.000132 | 2 | 4 | EPDGW-CCF-DG-B-AAC | Loss of power from DG B and AACDG due to inter-unit CCF | 0.000132 | 2 | 5 | EPDGW-CCF-DG-AB-AAC | All DGs fail to start due to inter-unit CCF | 0.000132 | 2 | 6 | 2-EPDGW-CCF-DG-C-AAC | Loss of power from DG C and AACDG due to inter-unit CCF | 0.000132 | 2 | 7 | 2-EPDGW-CCF-DG-D-AAC | Loss of power from DG D and AACDG due to inter-unit CCF | 0.000132 | 2 | 8 | 2-EPDGW-CCF-DG-AB-AAC | Loss of power from DG C and AACDG due to inter-unit CCF | 0.000132 | 2 |
|
|