Research Article

ELSMOR European Project: Experimental Results on an Innovative Decay Heat Removal System Based on a Plate-Type Heat Exchanger

Table 1

Estimated measurement uncertainties for the main ELSMOR data.

QuantityVariableUnitsMeasureExpanded uncertaintyU (%)

Primary side pressureP_001MPa11.920.010.1
Secondary side pressureP_003MPa6.450.010.2
S-CSG primary side differential pressureDP_021kPa22.260.030.1
S-CSG secondary side differential pressureDP_020kPa6.210.040.6
S-CSG primary side inlet temperatureTF_074°C310.90.150.0
S-CSG primary side outlet temperatureTF_075°C281.70.150.1
S-CSG secondary side inlet temperatureTF_070°C266.30.150.1
S-CSG secondary side outlet temperatureTF_071°C280.30.150.1
Vertical tube HX inlet temperatureTF_072°C280.30.150.1
Vertical tube HX outlet temperatureTF_068°C70.20.120.2
Pool water levelL_001m4.010.061.4
Pool water massM_001kg3008391.3
Pool water average temperatureT_ave°C99.62.82.8
S-CSG primary side flowrateF_011kg/s3.5760.1714.8
S-CSG secondary side flowrateF_007kg/s0.5550.0071.3
PS S-CSG powerW_CSGkW575305.2