Estimated measurement uncertainties for the main ELSMOR data.
| Quantity | Variable | Units | Measure | Expanded uncertainty | U (%) |
| Primary side pressure | P_001 | MPa | 11.92 | 0.01 | 0.1 | Secondary side pressure | P_003 | MPa | 6.45 | 0.01 | 0.2 | S-CSG primary side differential pressure | DP_021 | kPa | 22.26 | 0.03 | 0.1 | S-CSG secondary side differential pressure | DP_020 | kPa | 6.21 | 0.04 | 0.6 | S-CSG primary side inlet temperature | TF_074 | °C | 310.9 | 0.15 | 0.0 | S-CSG primary side outlet temperature | TF_075 | °C | 281.7 | 0.15 | 0.1 | S-CSG secondary side inlet temperature | TF_070 | °C | 266.3 | 0.15 | 0.1 | S-CSG secondary side outlet temperature | TF_071 | °C | 280.3 | 0.15 | 0.1 | Vertical tube HX inlet temperature | TF_072 | °C | 280.3 | 0.15 | 0.1 | Vertical tube HX outlet temperature | TF_068 | °C | 70.2 | 0.12 | 0.2 | Pool water level | L_001 | m | 4.01 | 0.06 | 1.4 | Pool water mass | M_001 | kg | 3008 | 39 | 1.3 | Pool water average temperature | T_ave | °C | 99.6 | 2.8 | 2.8 | S-CSG primary side flowrate | F_011 | kg/s | 3.576 | 0.171 | 4.8 | S-CSG secondary side flowrate | F_007 | kg/s | 0.555 | 0.007 | 1.3 | PS S-CSG power | W_CSG | kW | 575 | 30 | 5.2 |
|
|