Review Article
Closed-Form Formula of the Transverse Dynamic Stiffness of a Shallowly Inclined Taut Cable
Table 3
A comparison between the calculated and measured dynamic stiffness.
| | Frequency | 1.8632 | 2.0961 | 2.3290 | 2.5619 | 2.7948 |
| Measured | | | | | | Method one | | | | | | Relative error (%) | | | | | | Method two | | | | | | Relative error (%) | | | | | | Method three | | | | | | Relative error (%) | 5.828 | 5.953 | 5.363 | 4.700 | 5.931 |
|
|