Review Article

Closed-Form Formula of the Transverse Dynamic Stiffness of a Shallowly Inclined Taut Cable

Table 3

A comparison between the calculated and measured dynamic stiffness.

Frequency
1.86322.09612.32902.56192.7948

Measured
Method one
Relative error (%)
Method two
Relative error (%)
Method three
Relative error (%)5.8285.9535.3634.7005.931