Research Article

Investigation of Effect on Vibrational Behavior of Giant Magnetostrictive Transducers

Table 2

Resonance frequency in different temperature (10.34 MPa prestress, 40 kA/m magnetic bias).

(°C)Young modulus (GPa)FEM prediction of resonance frequency (Hz)Analytical prediction of resonance frequency (Hz)

2040.581888331
4042.481918335
6044.481948340
8045.281958342