Research Article
Automatic Condition Monitoring of Industrial Rolling-Element Bearings Using Motor’s Vibration and Current Analysis
Table 4
Calculated
s within [0, 310 Hz], 20 Hz motor input, free load condition, and axial vibration measurements.
| CF (Hz ± 1.5%) | No fault (%) | Inner (%) | Outer (%) |
| : 40.67 | 18.75 | 8.33 | 9.52 | : 61.39 | 18.12 | 11.11 | 80.95 | : 81.34 | 100.63 | 30.56 | 20.24 | : 98.60 | 87.50 | 44.44 | 23.81 | : 122.01/122.78 | 23.75 | 15.28 | 66.67 | : 162.68 | 5.10 | 6.94 | 7.14 | : 184.17 | 1.20 | 9.72 | 35.71 | : 197.20 | −1.15 | 36.11 | 11.90 | : 203.35 | 1.16 | 10.56 | 7.11 | : 244.02/245.56 | 37.5 | 17.22 | 45.24 | : 295.80 | 18.75 | 20.83 | 16.67 | : 306.95 | 4.60 | 9.12 | 51.01 |
|
|