Research Article

Sensor Placement Optimization of Vibration Test on Medium-Speed Mill

Table 5

Comparison of vibration displacement between the finite element analysis results and the field test results.

Measuring points2()/mm3()/mm4()/mm2()/mm3()/mm4()/mm2()/mm

Test results0.0620.1320.4210.1030.2260.2460.106
Calculation results0.0510.1010.3850.0800.1690.2020.082
Error (%)17.523.58.622.425.118.322.6